subject
Engineering, 23.11.2019 00:31 MuntazerMehdi9746

Re-consider the dc motor drive system (k = 147,7 = 0.1) that you examined in problem 2. the goal is to design a feedback controller g (s) to meet the following performance requirements:
p1. the steady-state error caused by a unit constant disturbance torque t, (s) should be zero (steady-state performance specifications).
p2. the unit step response of the closed-loop system to the reference input should have an overshoot of 15% and a 2% setting time of 0.1 sec (transient performance specifications).
a. using the closed-loop transfer function g (s) from the disturbance torque t(s) to the output y(s), obtain the steady-state error caused by a unit constant disturbance torque t, (s) when a pd feedback controller g (s)= k, +ky is used. if you are doing correctly, you will find that the steady-state error obtained is not zero and thus a pd controller cannot satisfy the steady-state performance requirement p1.
b. to satisfy the steady-state performance requirement p1, we can use the following proportional plus integral and derivative (pid) feedback controller: g (5)=k, +k,+k, which can implemented by applying the following physical control input to the plant: u(t)=k_(6)+k„¢t) + k, ſe(t)dt or u(s)=k+k»s+k, e(s) obtain the closed-loop transfer functions gr(s) and g (s) when the above pid feedback controller is used.
c. show that with the above pid controller, as long as the closed-loop system is stable, the steady- state performance requirement p1 will be satisfied.
d. to determine the pid gains kp, k, and k, to satisfy the transient performance requirement p2, we will use the pole placement technique. your denominator of the closed loop transfer function should be third order so you will need to place three poles. determine a desired form for the denominator of the closed loop transfer function such that the dominant poles will be second order with an overshoot of 15% and a 2% setting time of 0.1 sec (as prescribed by requirement p2). place a third pole at -100.
e. determine the pid gains kp, k, and k, which will produce the desired pole locations from part d.

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, viicborella
Steel is coated with a thin layer of ceramic to protect against corrosion. what do you expect to happen to the coating when the temperature of the steel is increased significantly? explain.
Answers: 1
image
Engineering, 04.07.2019 18:10, Talos02
Burgers vector is generally parallel to the dislocation line. a)-true b)-false
Answers: 2
image
Engineering, 04.07.2019 18:10, soreese02
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
image
Engineering, 04.07.2019 18:10, Strick1530
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
You know the right answer?
Re-consider the dc motor drive system (k = 147,7 = 0.1) that you examined in problem 2. the goal is...

Questions in other subjects:

Konu
Mathematics, 12.12.2019 16:31