subject
Engineering, 23.10.2019 18:00 ks970065

Amanaged service provider is designing a log aggregation service for customers who no longer want to manage an internal siem infrastructure. the provider expects that customers will send all types of logs to them, and that log files could contain very sensitive entries. customers have indicated they want on-premises and cloud-based infrastructure logs to be stored in this new service. an engineer, who is designing the new service, is deciding how to segment customers.

which of the following is the best statement for the engineer to take into consideration?

single-tenancy is often more expensive and has less efficient resource utilization. multi-tenancy may increase the risk of cross-customer exposure in the event of service vulnerabilities.
the managed service provider should outsource security of the platform to an existing cloud company. this will allow the new log service to be launched faster and with well-tested security controls.
due to the likelihood of large log volumes, the service provider should use a multi-tenancy model for the data storage tier, enable data deduplication for storage cost efficiencies, and encrypt data at rest.
the most secure design approach would be to give customers on-premises appliances, install agents on endpoints, and then remotely manage the service via a vpn

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, Fahaddie
The thermal expansion or contraction of a given metal is a function of the f a)-density b)-initial temperature c)- temperature difference d)- linear coefficient of thermal expansion e)- final temperature f)- original length
Answers: 2
image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
image
Engineering, 04.07.2019 18:20, ashleyjaslin
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
image
Engineering, 04.07.2019 18:20, jessie8022
Apiston-cylinder device contains 0.1 m3 of liquid water and 0.9 m3 of water vapor in equilibrium at 800 kpa. heat is transferred at constant pressure until the temperature of water reaches 350 °c. determine (a) the quality of water at the initial state (b) the work associated with this process, (c) the heat associated with this process.
Answers: 2
You know the right answer?
Amanaged service provider is designing a log aggregation service for customers who no longer want to...

Questions in other subjects: