subject
Engineering, 09.08.2019 03:20 chony83

An air conditioner with refrigerant-134a (r-134a) as the working fluid is used to keep a room at 26°c by rejecting the waste heat to the outside air at 34°c. the room is gaining heat through the walls and the windows at a rate of 250 kj/min while the heat generated by the computer, tv, and lights amounts to 900 w. an unknown amount of heat is also generated by the people in the room. the condenser and evaporator pressures are 1200 and 500 kpa, respectively. the refrigerant is saturated liquid at the condenser exit and saturated vapor at the compressor inlet. if the refrigerant enters the compressor at a rate of 100 l/min and the isentropic efficiency of the compressor is 75 percent, determine (a) the temperature of the refrigerant at the compressor exit, (b) the rate of heat generation by the people in the room, (c) the cop of the air conditioner, and (d) the minimum volume flow rate of the refrigerant at the compressor inlet for the same compressor inlet and exit conditions

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, dval1146
You are making beer. the first step is filling the glass carboy with the liquid wort. the internal diameter of the carboy is 15 in., and you wish to fill it up to a depth of 2 ft. if your wort is drawn from the kettle using a siphon process that flows at 3 gpm, how long will it take to fill?
Answers: 1
image
Engineering, 04.07.2019 18:20, moneywaydaedae
Air is compressed isentropically from an initial state of 300 k and 101 kpa to a final temperature of 1000 k. determine the final pressure using the following approaches: (a) approximate analysis (using properties at the average temperature) (b) exact analysis
Answers: 1
image
Engineering, 04.07.2019 19:20, mariahmimibrooks
Liquid flows at steady state at a rate of 2 lb/'s through a pump, which operates to raise the elevation of the liquid 100 ft from control volume inlet to exit. the liquid specific enthalpy at the inlet is 40.09 btu/lb and at the exit is 40.94 btub. the pump requires 3 btu/s of power to operate. if kinetic energy effects are negligible and gravitational acceleration is 32.174 tt/s, the heat transfer rate associated with this steady state process is most closely 1)-2,02 btu/s from the liquid to the surroundings 2)-3.98 btu/s from the surroundings to the liquid. 3)-4.96 btu/s from the surroundings to the liquid. 4)-1.04 btu/s from the liquid to the surroundings.
Answers: 2
image
Engineering, 04.07.2019 19:20, dndndndnxmnc
The process in which the system pressure remain constant is called a)-isobaric b)-isochoric c)-isolated d)-isothermal
Answers: 3
You know the right answer?
An air conditioner with refrigerant-134a (r-134a) as the working fluid is used to keep a room at 26°...