subject
Physics, 18.11.2020 18:10 jiggadess3440

SOMEONE PLZ HELP , I HAVE 4 HW DUE TMR BC MY TEACHER JUST GIVE ME A VERY SHORT TIME TO DO THE WORK . 50POINTS


SOMEONE PLZ HELP , I HAVE 4 HW DUE TMR BC MY TEACHER JUST GIVE ME A VERY SHORT TIME TO DO THE WORK

ansver
Answers: 3

Other questions on the subject: Physics

image
Physics, 22.06.2019 03:10, joho38
Athin plate moves between two parallel, horizontal, stationary flat surfaces at a constant velocity of v = 7.5 m/s. the two stationary surfaces are spaced 4 cm apart, and the medium between them is filled with oil whose viscosity is 0.9 n·s/m2. the part of the plate immersed in oil at any given time is 2 m long and 0.5 m wide. if the plate moves through the mid-plane between the surfaces, determine the force required to maintain this motion. what would your response be if the plate was 1 cm from the bottom surface (h2) and 3 cm from the top surface (h1)? if the plate moves through the mid-plane between the surfaces, the force required to maintain the motion will be n. if the plate was 1 cm from the bottom surface (h2) and 3 cm from the top (h1) surface, the force required to maintain the motion would be n.
Answers: 2
image
Physics, 22.06.2019 14:30, mangowammy
What conclusion can be made based on the temperature of soil when the light hits the soil at 0°, 45°, and 90° angles in section 2 of the experiment? did your results support your hypothesis? why or why not?
Answers: 1
image
Physics, 23.06.2019 04:40, lol9691
Abody covers a semicircle of radius 7cm in 5s .find its linear speed
Answers: 1
image
Physics, 23.06.2019 07:00, hockejoh000
Conventional hot-water heaters consist of a tank of water maintained at a fixed temperature. the hot water is to be used when needed. the drawback is that energy is wasted because the tank loses heat when it is not in use, and you can run out of hot water if you use too much. some utility companies are encouraging the use of on-demand water heaters (also known as flash heaters), which consist of heating units to heat the water as you use it. no water tank is involved, so no heat is wasted. a typical household shower flow rate is 2.50 gal/min (9.46 l/min ) with the tap water being heated from 51.0 ˚f (10.6 ˚c) to 120 ˚f (48.9 ˚c) by the on-demand heater. what rate of heat input (either electrical of from gas) is required to operate such a unit, assuming that all the heat goes into the water?
Answers: 3
You know the right answer?
SOMEONE PLZ HELP , I HAVE 4 HW DUE TMR BC MY TEACHER JUST GIVE ME A VERY SHORT TIME TO DO THE WORK ....

Questions in other subjects:

Konu
Mathematics, 21.11.2020 05:30
Konu
Mathematics, 21.11.2020 05:30