Air enters the compressor of a test facility at 80 °F and 14.5 psia. It is then compressed isentropically to 500 psia and transported to the test cell. At the cell inlet some of the gas is pulled off in a tube for humidity measurements. The tube is maintained at a temperature of 200 °F into the test cell where the sensor is located. Is that line temperature sufficient to ensure a successful measurement of the cell entrance humidity?

ansver
Answers: 1

Other questions on the subject: Physics

image
Physics, 21.06.2019 23:00, POOPINgligma
Atrain departs from its station at a constant acceleration of 5 m/s. what is the speed of the train at the end of 20s?
Answers: 1
image
Physics, 22.06.2019 11:20, ignacio73
How to tell if a molecule is polar or nonpolar with electronegativity
Answers: 2
image
Physics, 22.06.2019 16:30, jetblackcap
When conducting an investigation to determine which type of fertilizer produces the most flowers on a plant, which variable would be graphed on the x-axis once you collected the data? a. type of fertilizer b. amount of flowers c. amount of water d. number of days that the plants grew
Answers: 1
image
Physics, 22.06.2019 17:00, cwibs
Adiver named jacques observes a bubble of air rising from the bottom of a lake (where the absolute pressure is 3.50 atm) to the surface (where the pressure is 1.00 atm). the temperature at the bottom is 4.00 ∘c, and the temperature at the surface is 23.0 ∘c. what is the ratio of the volume of the bubble as it reaches the surface (vs) to its volume at the bottom (vb)? if jaques were to hold his breath the air in his lungs would be kept at a constant temperature. would it be safe for jacques to hold his breath while ascending from the bottom of the lake to the surface?
Answers: 1
You know the right answer?
Air enters the compressor of a test facility at 80 °F and 14.5 psia. It is then compressed isentropi...