subject
Physics, 03.07.2019 06:20 eliseeimbody

Aquantity of gas (mean molecular weight 36.2) is compressed according to the law pv = constant, the initial pressure and volume being 1.03 bar and 0.98 m respectively. the temperature at the start of compression is 17°c and at the end it is 115°c. the amount of heat rejected during compression is 3.78 kj, cp = 0.92. calculate (i) value of n (ii) final pressure (iii) change in entropy

ansver
Answers: 1

Other questions on the subject: Physics

image
Physics, 21.06.2019 13:50, Corgilover1234
Ahot-air balloon is drifting straight downward with a constant speed of 2.40 m/s. when the balloon is 7.63 m above the ground, the balloonist decides to drop one of the ballast sandbags to the ground below. how much time elapses before the sandbag hits the ground?
Answers: 1
image
Physics, 21.06.2019 18:00, kadinmorgan
Aproton is projected toward a fixed nucleus of charge +ze with velocity vo. initially the two particles are very far apart. when the proton is a distance r from the nucleus its velocity has decreased to 1/2vo. how far from the nucleus will the proton be when its velocity has dropped to 1/4vo?
Answers: 3
image
Physics, 22.06.2019 11:20, cjd1214812148
The ultracentrifuge is an important tool for separating and analyzing proteins. because of the enormous centripetal accelerations, the centrifuge must be carefully balanced, with each sample matched by a sample of identical mass on the opposite side. any difference in the masses of opposing samples creates a net force on the shaft of the rotor, potentially leading to a catastrophic failure of the apparatus. suppose a scientist makes a slight error in sample preparation and one sample has a mass 10 mg larger than the opposing sample. if the samples are 12 cm from the axis of the rotor and the ultracentrifuge spins at 70,000 rpm, what is the magnitude of the net force on the rotor due to the unbalanced samples? ( be thorough on your answer)
Answers: 3
image
Physics, 22.06.2019 16:50, lizzepacheco
Acommercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at -35°c by rejecting waste heat to cooling water that enters the condenser at 18°c at a rate of 0.25 kg/s and leaves at 26°c. the refrigerant enters the condenser at 1.2 mpa and 50°c. if the compressor consumes 3.3 kw of power, determine (a) the mass flow rate of the refrigerant, (b) the refrigeration load, (c) the cop, and (d) the minimum power input to the compressor for the same refrigeration load.
Answers: 2
You know the right answer?
Aquantity of gas (mean molecular weight 36.2) is compressed according to the law pv = constant, the...

Questions in other subjects:

Konu
Mathematics, 11.03.2021 22:20
Konu
Mathematics, 11.03.2021 22:20