1. Flexural Strenght Determination :
Test prism No. 1: Length 159.4 mm Width: 40.0 mm Height: 40.0mm
Mass : 582 g Maximum Load: 3.6 KN
Test Prism No. 2: Length : 159.4 mm Width: 40.0 mm Height: 40.0mm
Mass: 575 g Maximum Load: 3.6 KN
Test Prism No. 3: Length : 159.6 mm Width: 40.0 mm Height: 39.9 mm
Mass: 586 g Maximum Load: 3.6 KN
2. Compressive Strength Determination :
Maximum Load (prism halves) (kN) : 82.0 84.3 75.7 80.4 71.8 74.2
Decide, if the test is valid according EN 197-1!
Decide, if the cement complies with the requirements of EN 197-1
Answers: 3
Engineering, 04.07.2019 18:10, yasminothman02
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
Engineering, 04.07.2019 18:10, skpdancer1605
Ariver flows from north to south at 8 km/h. a boat is to cross this river from west to east at a speed of 20 km/h (speed of the boat with respect to the earth/ground). at what angle (in degrees) must the boat be pointed upstream such that it will proceed directly across the river (hint: find the speed of the boat with respect to water/river)? a 288 b. 21.8 c. 326 d. 30.2
Answers: 3
Engineering, 04.07.2019 18:10, soreese02
An ideal otto cycle with air as the working fluid has a compression ratio of 8. the minimum and maximum temperatures in the cycle are 300 k and 1340 k. use constant specific heats at room temperature to determine (a) the amount of heat transferred to the air during the heat- addition kj/kg, (b) the thermal efficiency, and (c) the thermal efficiency of a carnot cycle ope limits. process, in rating between the same temperature
Answers: 2
Engineering, 04.07.2019 18:10, Larkinlover703
Items are similar to the free issue items, but their access is limited. (clo5) a)-bin stock items free issue b)-bin stock controlled issue c)-critical or insurance spares d)-rebuildable spares e)-consumables
Answers: 1
1. Flexural Strenght Determination :
Test prism No. 1: Length 159.4 mm Width: 40.0 mm Height: 40.0...
Mathematics, 12.07.2019 06:30
Mathematics, 12.07.2019 06:30
Mathematics, 12.07.2019 06:30
Mathematics, 12.07.2019 06:30
Chemistry, 12.07.2019 06:30
History, 12.07.2019 06:30
Mathematics, 12.07.2019 06:30
Mathematics, 12.07.2019 06:30