An estimate of the uncertainty for the concentration of an unknown sample can be determined based on the uncertainty in the calibration data set and the unknown sample analysis. The uncertainty (Sx) value is unitless when using the internal standard method of calibration. The uncertainty needs to be expressed in terms of the concentration units used for the standards (i. e. ppm). Calculated the uncertainty value in terms of concentration (Sc) for the diluted AND undiluted sample based on the following information. Uncertainty (Sx; unitless) based on the calibration data set and the unknown sample. Sx = 0.0152

Sample preparation: A whiskey sample is prepared for analysis by GC-FID using the internal standard method of calibration. A 20 mL sample is transferred using a volumetric pipet to a 50 mL volumetric flask. A volume of stock solution of the internal standard is added to the sample flask. The flask is diluted to volume.

Concentration of the internal standard in the diluted unknown = 500 ppm.

A. Sc(dilute) = 8 ppm, Sc(undilute) = 20 ppm
B. Sc(dilute) = 7 ppm, Sc(undilute) = 19 ppm
C. Sc(dilute) = 7.75 ppm, Sc(undilute) = 19.31 ppm
D. Sc(dilute) = 8 ppm, Sc(undilute) = 30 ppm

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, danksans7011
The mass flow rate of the fluid remains constant in all steady flow process. a)- true b)- false
Answers: 1
image
Engineering, 04.07.2019 18:10, viicborella
Steel is coated with a thin layer of ceramic to protect against corrosion. what do you expect to happen to the coating when the temperature of the steel is increased significantly? explain.
Answers: 1
image
Engineering, 04.07.2019 18:10, agpraga23ovv65c
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
image
Engineering, 04.07.2019 18:10, Strick1530
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.