![subject](/tpl/images/cats/User.png)
Engineering, 03.12.2021 18:00 heberavilesramirez52
Technician A says that hoods are designed with reinforcements to prevent folding during a collision. Technician B says that some hoods are made from reinforced plastic. Who is right?
![ansver](/tpl/images/cats/User.png)
Answers: 1
![](/tpl/images/ask_question.png)
![](/tpl/images/ask_question_mob.png)
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, hayleymckee
Steam enters a converging nozzle at 3.0 mpa and 500°c with a at 1.8 mpa. for a nozzle exit area of 32 cm2, determine the exit velocity, mass flow rate, and exit mach number if the nozzle: negligible velocity, and it exits (a) is isentropic (b) has an efficiency of 94 percent
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, cdyshaylia55
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
You know the right answer?
Technician A says that hoods are designed with reinforcements to prevent folding during a collision....
Questions in other subjects:
![Konu](/tpl/images/cats/en.png)
English, 07.05.2020 02:05
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/biologiya.png)
Biology, 07.05.2020 02:05
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/istoriya.png)
History, 07.05.2020 02:05
![Konu](/tpl/images/cats/en.png)
English, 07.05.2020 02:05
![Konu](/tpl/images/cats/himiya.png)
Chemistry, 07.05.2020 02:05
![Konu](/tpl/images/cats/mat.png)