subject
Engineering, 24.05.2021 14:00 mjweed3381

You are running an experimental fixed-bed adsorption column that enables you to sample the liquid along the length of the bed. These samples then may be analyzed for solute concentration. Based on your analysis, you determine that 60% of the bed comes to equilibrium with the feed solute concentration at breakthrough. Required:
a. What is the corresponding bed efficiency (fraction of bed utilized)?
b. If the bed performance described above was achieved under conditions where the adsorption isotherm is roughly linear with K = 100, can q be improved to 0.95 by changing K if all else is held constant? Explain.
c. How does the slope of the breakthrough curve change with K? Discuss this issue

with regard to fixed bed adsorption column operation and performance.

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, lerasteidl
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
image
Engineering, 04.07.2019 18:20, aly95
An engine runs on the ideal diesel cycle. the cycle has a compression ratio of 20 and a cutoff ratio of 2. the highest temperature in the cycle is 1200 k. if the heat into the system is 300 kj/kg of working fluid and using variable specific heats determine the work produced per mass of working fluid
Answers: 3
image
Engineering, 04.07.2019 19:10, jimena15
10 kg of co2 is initially contained at 400 kpa and 300 k. the gas constant for carbon dioxide is 189 j/lkg k) and has a specific heat ratio, k, of 1.289. isentropic expansion then occurs until the pressure is 200 kpa. a) determine the initial volume of co2 in m. b) determine the final temperature in k. c) determine the work done by the system during the expansion kl.
Answers: 2
image
Engineering, 04.07.2019 19:20, lordcaos066
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
You know the right answer?
You are running an experimental fixed-bed adsorption column that enables you to sample the liquid al...

Questions in other subjects:

Konu
Mathematics, 11.12.2019 20:31
Konu
Mathematics, 11.12.2019 20:31