subject
Engineering, 23.04.2021 15:40 haileysolis5

An arrival rate of 720 veh/h arrive at a single lane signalized approach that is controlled by a traffic signal that operates at a cycle length of 60 seconds and a 50:50 green split. The amber and all-red interval is 5 seconds. The unopposed saturation flow rate was measured to be 1800 veh/h/lane with a start-loss 2 seconds and end gain of 3 seconds, respectively. For the approach do the following for a single cycle length: a. Compute the maximum queue size formed upstream the traffic signal.
b. Compute the time required to dissipate the queue.
c. Compute the average vehicle delay experienced by vehicles traveling on the approach using the macroscopic procedures that were described in the class.
d. Compute the average vehicle delay experienced by vehicles traveling on the approach by tracking the arrival and departure times of each vehicle. Assume the first vehicle arrives at the midheadway after the red interval starts.
e. Repeat part (d) considering the first vehicle arrival ranges from 0 to 5 seconds. Comment on the sensitivity of delay estimates to the arrival time of the first vehicle.
f. Compute the number of vehicles that come to a complete stop during the cycle length.
g. Compute the maximum delay experienced by a vehicle.
h. What is the delay experienced by the third vehicle in queue assuming that the first vehicle arrives at the start of the red.
The Cycle length is 60 seconds. The problem should be solved fo a single cycle length.

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, danksans7011
The mass flow rate of the fluid remains constant in all steady flow process. a)- true b)- false
Answers: 1
image
Engineering, 04.07.2019 18:10, jadeochoa4466
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
image
Engineering, 04.07.2019 18:10, ayoismeisjjjjuan
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
You know the right answer?
An arrival rate of 720 veh/h arrive at a single lane signalized approach that is controlled by a tra...

Questions in other subjects:

Konu
Mathematics, 12.04.2021 20:10