subject
Engineering, 16.04.2021 20:40 mooreadrian412

The feed enters at its bubble-point temperature; vapour from the top tray enters a total condenser; the resulting liquid (distillate and reflux) leaves at its bubble point of 32 C. The reboiler operates at a temperature of 126 C and the top tray temperature is 63 C. The column operates at a pressure of 320 kPa and pressure drops may be neglected. a) Identify the key components.
b) Calculate the minimum reflux ratio.


The feed enters at its bubble-point temperature; vapour from the top tray enters a total condenser;

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, BardiFan
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
image
Engineering, 04.07.2019 19:10, nbunny7208
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces. a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
image
Engineering, 04.07.2019 19:20, lordcaos066
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
image
Engineering, 06.07.2019 03:20, cherkaouinazihp387bk
Figure out the odd statement about ceramics in the following (a) good insulators of heat and electricity (b) usually less desire than metals (c) ductile in nature (d) contains both metallic and nonmetallic elements
Answers: 3
You know the right answer?
The feed enters at its bubble-point temperature; vapour from the top tray enters a total condenser;...

Questions in other subjects: