g A reactor has an overall hydraulic residence time t , based on the total volume of water in the reactor and the total flow through it. The reactor can be reasonably represented as two ideal CMFR reactorsin parallel. 60% of influent flow passes through the first CMFR with residence time of t1. 40% of influent flow passes through the second CMFR with residence time of t2. (a) Write the overall E(t) equation for the two CMFRs in parallel (Hint: in a parallel system, the events occurring in each unit add up proportionately to yield the overall function). (3 points) (b) What fraction of the water that enters the reactor stays there for a time t < t. Assume t

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 19:10, jennymares
Abarometer contains mercury with a density of 13600 kg/m3. atmospheric conditions are 95.8 kpa and 20 °c at 20 °c, the vapor pressure of the mercury is 0.000173 kpa. the column of mercury will rise to a height of most nearly. select one: a)- 0.38 m b)- 0.82 m c)- 0.48 m d)- 0.72 m
Answers: 1
image
Engineering, 04.07.2019 19:20, carterdaw
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
image
Engineering, 04.07.2019 19:20, amandaaarmentaa
Acircular pipe of 30mm outside diameter is placed in an airstream at 30 c and latm pressure. the air moves in cross flow over the pipe at 20 m/s, while the outer surface of the pipe is maintained at 110 c. what is the drag force exerted on the pipe per unit length? what is the rate of heat transfer from the pipe per unit length?
Answers: 1
image
Engineering, 06.07.2019 03:30, sipstick971
An ammonia compressor has a 5% clearance volume and displacement rate of 80 l/s and pumps against a condensing temperature of 40°c. for two different temperatures of -10°c and 10°c, compute the mass flow rate of refrigerant assuming the clearance volumetric efficiency applies. discharge specific volume corresponding to-10°c and 10°c are 112.5 l/kg and 95 l/kg, respectively.
Answers: 2