subject
Engineering, 09.02.2021 05:50 bryneosburn

A metal rod of length 2L, diameter D, and thermal conductivity k is inserted into a perfectly insulating wall, exposing one-half of its length to an air stream that is of temperature T and provides a convection co- efficient h at the surface of the rod. An electro- magnetic field induces volumetric energy generation at a uniform rate q within the embedded portion of the rod. 100 WWm2K Rod, D, k L 50 mm D 5 mm k 25 WNm. K 1 x 106 wm3 (a) Derive an expression for the steady-state tempera- ture Tb at the base of the exposed half of the rod. The exposed region may be approximated as a very long fin. (b) Derive an expression for the steady-state tempera- ture Ta at the end of the embedded half of the rod. (c) Using numerical values provided in the schematic, 3 plot the temperature distribution in the rod and de- scribe key features of the distribution. Does the rod behave as a very long fin?

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, viicborella
Steel is coated with a thin layer of ceramic to protect against corrosion. what do you expect to happen to the coating when the temperature of the steel is increased significantly? explain.
Answers: 1
image
Engineering, 04.07.2019 18:10, niyawilliams23
Asingle-geared blanking press has a stroke of 200 mm and a rated capacity of 320 kn. a cam driven ram is assumed to be capable of delivering the full press load at constant force during the last 15 percent of a constant-velocity stroke. the camshaft has an average speed of 90 rev/min and is geared to the flywheel shaft at a 6: 1 ratio. the total work done is to include an allowance of 16 percent for friction a) estimate the maximum energy fluctuation b) find the rim weight for an effective diameter of 1.2 m and a coefficient of speed fluctuation of 0.10
Answers: 1
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
image
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
You know the right answer?
A metal rod of length 2L, diameter D, and thermal conductivity k is inserted into a perfectly insula...