Engineering, 05.02.2021 21:10 minerrage43

After answering the following questions, review the laboratory exercise procedures and p how you will use the experience gained in these calculations to find the values sought. 1. Using the information provided in the Background section, calculate the average voltage, the avera absolute voltage, and the rms voltage values for the symmetrical sine, square, and triangular waveforr assuming that the peak value of each waveform is 2V.
Table 2.1: Calculated Voltage Values Average Voltage Average Absolute Voltage RMS Voltage Sine Square Triangular 6
2. Compute the RMS voltage value that would be reported by non-true rms voltmeters, assuming the peak value of each waveform is 2V. You may use the equations derived in the Background sec for these calculations.
Table 2.2: Reported Voltage Value by non-true RMS voltmeters Reported RMS Voltage Sine Square Triangular

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, xboxdude06
Slip occurs via two partial dislocations because of (a) the shorter path of the partial dislocation lines; (b) the lower energy state through partial dislocations; (c) the charge balance.
Answers: 1
image
Engineering, 04.07.2019 18:10, nandalabella06
True or false (explain) (110)[111] is a slip system in bcc metals . the {111} family in fcc contains 8 planes. resolved shear stress (rss) in single crystals is just related to the applied stress. critical resolved shear stress (crss) in single crystal metals is direct proportional to the number of defects in the structure
Answers: 2
image
Engineering, 04.07.2019 19:10, ndaha
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
image
Engineering, 04.07.2019 19:10, nhester3401
Agas is compressed from vi 0.3 m, p 1 bar to of v2 0.1 m3, p2--3 bar. pressure and volume are related linearly during the process. for the gas, find the work, in kj.
Answers: 2
You know the right answer?
After answering the following questions, review the laboratory exercise procedures and p how you wil...

Questions in other subjects:

Konu
Mathematics, 16.11.2020 23:40
Konu
Mathematics, 16.11.2020 23:40
Konu
Spanish, 16.11.2020 23:40
Konu
Mathematics, 16.11.2020 23:40
Konu
Arts, 16.11.2020 23:40