subject
Engineering, 03.02.2021 03:00 hmu323

Se apoya un edificio en una losa de cimentación de concreto reforzado que cubre un área de 12x24mts. el subsuelo es una arcilla que tiene una Resistencia a la Compresión Simple de 9.3 ton/m2. La presión en el suelo, debido al peso del edificio y a las cargas que va a soportar será de 11.37 ton/m2. en la base de la cimentación. Si el peso volumétrico del suelo excavado es 1950 kg/m3. ¿a qué profundidad deberá desplantarse el lecho inferior de la cimentación.

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, koolgurl2003
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
image
Engineering, 04.07.2019 18:10, jojoangelique13
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
image
Engineering, 04.07.2019 18:20, samueltaye
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
Se apoya un edificio en una losa de cimentación de concreto reforzado que cubre un área de 12x24m...

Questions in other subjects:

Konu
English, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01
Konu
History, 13.09.2020 16:01
Konu
Mathematics, 13.09.2020 16:01