subject
Engineering, 14.01.2021 09:10 jacckiie5176

Considere un colector solar de aire que tiene 1 m de ancho y 5 m de largo y un espaciamiento constante de 3 cm entre la cubierta de vidrio y la placa del propio colector. El aire entra en el colector a 30°C a razón de 0.15m3 /s por el borde de 1 m de ancho y fluye a lo largo del paso de 5 m de largo. Si las temperaturas promedio de la cubierta de vidrio y de la placa del colector son de 20°C y 60°C, respectivamente, determine a) la razón neta de la transferencia de calor hacia el aire conforme fluye por el colector y b) la elevación de temperatura del aire conforme fluye a través del colector.

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, namira16
Which of the following controllers anticipates the future from the slope of errors over time? a)-proportional b)-on/off c)-integral d)-derivative.
Answers: 2
image
Engineering, 04.07.2019 19:10, pedropaulofpedrosapp
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg. m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 3
image
Engineering, 06.07.2019 03:30, aminsaad4253
Abrayton cycle operates with a regenerator on the air-standard with properties evaluated at 400 k. the tem- perature of the air entering the compressor is 350k while the temperature of the air exiting the compressor is 600 k. the temperature of the air entering the turbine is 1600 k. the overall cycle produced 600 kj/kg of net work out. assuming a regenerator effectiveness of 0.8, what is the temperature of the air before heat addition (combustion)? draw this process on a t - s diagram
Answers: 3
image
Engineering, 06.07.2019 05:20, emmanuel96
The inner surface of a 0.25m thick brick wall of a furnace is kept at 810ºc, when the outside surrounding air is at 22ºc. the convective heat transfer coefficient of the outer surface is 12 w/m2k and the thermal conductivity of the brick is 0.865 w/mk. neglect the convective resistance for the inner side of the furnace and assume that the problem is steady state and thermal radiation is neglected. (a)-sketch the system and calculate the rate of heat loss per unit wall area. (b)-calculate the temperature of the outer wall surface.
Answers: 2
You know the right answer?
Considere un colector solar de aire que tiene 1 m de ancho y 5 m de largo y un espaciamiento constan...

Questions in other subjects:

Konu
Chemistry, 22.02.2021 21:40