A three-phase 80 kVA transformer is rated to a primary voltage of 2.2 kV and a secondary voltage of 220 V. The transformer parameters are determined by open and short circuit tests. The results of the open and short circuit tests are: Short-Circuit Test (low-voltage side short-circuited; data measured at high-voltage side):
Vsc = 48 V Isc = 32 A Psc = 800 W
Open-Circuit Test (high-voltage side open; data measured at low-voltage side):
Voc = 220 V Ioc = 5.7 A Poc = 220 W

Required:
a. Determine the parameters of the equivalent circuit. Draw the equivalent circuit of the transformer.
b. Plot the voltage regulation and efficiency versus the load for both lagging and leading power factors of 0.6, 0.8, and 0.9. Obtain the maximum efficiency values. Assume the load voltage is equal to the rated secondary voltage of the transformer.
c. Assuming the primary rated voltage is being supplied to the transformer, determine the load voltage when the transformer carries half-load and the power factor is 0.8, both lagging and leading.

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, heidiburgos1own6c0
Fluids at rest possess no flow energy. a)- true b)- false
Answers: 3
image
Engineering, 04.07.2019 18:20, maciemarklin79981
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
image
Engineering, 04.07.2019 19:10, nida7864
An engine, weighing 3000 n, is supported on a pedestal mount. it has been observed that the engine induces vibration into the surrounding area through its pedestal at the maximum operating speed. determine the stiffness of the dynamic vibration absorber spring in (n/m) that will reduce the vibration when mounted on the pedestal. the magnitude of the exciting force is 250 n, and the amplitude of motion of the auxiliary mass is to be limited to 2 mm note: in this question type-in right numbers, no decimals, no fractions, no unit. approximate to right number if needed
Answers: 3
You know the right answer?
A three-phase 80 kVA transformer is rated to a primary voltage of 2.2 kV and a secondary voltage of...

Questions in other subjects: