Refrigerant-134a is throttled from the saturated liquid state at 700 kPa to a pressure of 160 kPa. Determine the page 253temperature drop during this process and the final specific volume of the refrigerant.

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, lerasteidl
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
image
Engineering, 04.07.2019 19:10, netflixacc0107
What is the major difference between thermoplastics and thermosetting plastics from the polymerization structure point of view?
Answers: 2
image
Engineering, 04.07.2019 19:10, nida7864
An engine, weighing 3000 n, is supported on a pedestal mount. it has been observed that the engine induces vibration into the surrounding area through its pedestal at the maximum operating speed. determine the stiffness of the dynamic vibration absorber spring in (n/m) that will reduce the vibration when mounted on the pedestal. the magnitude of the exciting force is 250 n, and the amplitude of motion of the auxiliary mass is to be limited to 2 mm note: in this question type-in right numbers, no decimals, no fractions, no unit. approximate to right number if needed
Answers: 3
image
Engineering, 04.07.2019 19:20, lordcaos066
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
You know the right answer?
Refrigerant-134a is throttled from the saturated liquid state at 700 kPa to a pressure of 160 kPa. D...

Questions in other subjects:

Konu
Mathematics, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01
Konu
History, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01
Konu
Mathematics, 10.09.2020 14:01