We want to evaluate the usage of nitrogen in the ISU Unit Operations laboratory. We are concerned that if a release of nitrogen occurs, the oxygen level will be reduced below the 19.5% allowed by OSHA. The laboratory has a floor area of 4800 ft2 and a volume of 74,300 ft3 . The ventilation rate is 1 ft3 /min for each square foot of laboratory floor space. A. We currently use a gas cylinder to deliver nitrogen. This cylinder contains a volume of 1.76 ft3 of nitrogen. The nitrogen in a full cylinder is pressurized to 2500 psig. Nitrogen behaves as an ideal gas under these conditions. Calculate the concentration of oxygen in the room if the cylinder fails catastrophically. Assume that the nitrogen released by the cylinder displaces the air in the lab. Is the oxygen concentration acceptable for this case?
B. We are proposing to replace a gascylinder with a small nitrogen plant. The plant is capable of producing 19.3 SCFM of nitrogen. If the nitrogen is all released into the laboratory instead of into the process that uses it, estimate the concentration of oxygen in the lab due to this continuous release of nitrogen. Is this acceptable? What about the local concentration around the vicinity of the leak?

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, aliceohern
The y form of iron is known as: a) ferrite b) cementite c) perlite d) austenite
Answers: 3
image
Engineering, 04.07.2019 12:10, Ryantimes2
On a average work day more than work place firs are reorted
Answers: 1
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 04.07.2019 18:10, anna22684
Water at 70°f and streams enter the mixing chamber at the same mass flow rate, determine the temperature and the quality of the exiting stream. 0 psia is heated in a chamber by mixing it with saturated water vapor at 20 psia. if both streams enters the mixing chamber at the same mass flow rate, determine the temperature and the quality of the existing system.
Answers: 2
You know the right answer?
We want to evaluate the usage of nitrogen in the ISU Unit Operations laboratory. We are concerned th...

Questions in other subjects:

Konu
Mathematics, 11.10.2021 20:50
Konu
English, 11.10.2021 20:50