Engineering, 20.09.2020 09:01 tonio638
A 50 mm × 45 mm × 20 mm cell phone charger has a surface temperature of Ts = 33°C when plugged into an electrical wall outlet but not in use. The surface of the charger is of emissivity ε = 0.92 and is subject to a free convection heat transfer coeffcient of h = 4.5 W/m2 ⋅K. The room air and wall temperatures are T[infinity] = 22°C and Tsur = 20°C, respectively. If electricity costs C = $0.18/kW ⋅ h, determine the daily cost of leaving the charger plugged in when not in use.
![ansver](/tpl/images/cats/User.png)
Answers: 2
![](/tpl/images/ask_question.png)
![](/tpl/images/ask_question_mob.png)
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, bckyanne3
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, jojoangelique13
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, cdyshaylia55
Water vapor initially at 10 bar and 400 °c is contained within a piston-cylinder assembly. the water lost heat to the surrounding according to isochoric (iso-volumetric) process until its temperature is 150 °c. the water is then condensed isothermally to saturated liquid. for the water as a system, calculate the work in kj/kg
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 19:10, nbunny7208
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces. a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
You know the right answer?
A 50 mm × 45 mm × 20 mm cell phone charger has a surface temperature of Ts = 33°C when plugged into...
Questions in other subjects:
![Konu](/tpl/images/cats/biologiya.png)
Biology, 12.04.2021 20:20
![Konu](/tpl/images/cats/pravo.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 12.04.2021 20:20
![Konu](/tpl/images/cats/geografiya.png)
Geography, 12.04.2021 20:20
![Konu](/tpl/images/cats/mat.png)
Mathematics, 12.04.2021 20:20
![Konu](/tpl/images/cats/biologiya.png)
![Konu](/tpl/images/cats/himiya.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 12.04.2021 20:20