A space has a sensible heating load of 60,000 W. The space is to be maintained at 21°C DB while the outdoor air is at 1°C DB and 20% RH. On coil air at 15°C is heated, humidified at the rate of 8 g/s, and supplied to the space at 31°C DB and 25% RH. Determine: a. The total amount of air supplied to the space; b. The amount of outdoor air supplied to the space; C. The relative humidity of the space. 3 Plot the process on a Psychrometric chart.

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, bryneosburn
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
image
Engineering, 04.07.2019 18:10, lillygrl100
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
image
Engineering, 04.07.2019 18:20, mjcbs21
What is the heat treatment of metals? what is the benefit of it? why and how it's useful? answer in details, do not write by hand.
Answers: 3
image
Engineering, 04.07.2019 19:10, thawkins79
Agas contained within a piston-cylinder assembly e end nation about same energy states, 1 and 2, where pi 10 bar, v undergoes two processes, a and b, between the sam 0.1 m3, ui-400 kj and p2 1 bar, v2 1.0 m2, u2 200 kj: process a: process from 1 to 2 during which the pressure- volume relation is pv constant process b: constant-volume process from state 1 to a pressure of 2 bar, followed by a linear pressure-volume process to +20 0 state 2 kinetic and potential energy effects can be ignored. for each of the processes a and b, (a) sketch the process on p-v coordinates, (b) evaluate the work, in kj, and (c) evaluate process the heat transfer, in kj
Answers: 2
You know the right answer?
A space has a sensible heating load of 60,000 W. The space is to be maintained at 21°C DB while the...

Questions in other subjects:

Konu
Mathematics, 07.01.2021 01:00
Konu
Mathematics, 07.01.2021 01:00
Konu
Mathematics, 07.01.2021 01:00
Konu
Mathematics, 07.01.2021 01:00