Engineering, 19.08.2020 18:01 brownvester44

A refrigeration plant operates in Pretoria on refrigerant R134a at an evaporator pressure of 105kPa (gauge) and a condensing pressure of 920 kPa (gauge). There is a sub-cooling of 3K with a superheat of the gas entering the compressor of 8K. The compressor is a four-cylinder reciprocating compressor with a bore of 67mm and a stroke of 57mm with an estimated capacity of 35kW. The compressor is directly coupled to an electric motor running at 1470rev/min and a power consumption of 19,5 kW. Calculate: 1. The clearance volume efficiency if the compressor clearance is 3,6% 2. The actual volumetric efficiency 3. The compression efficiency when the mechanical efficiency is 85% and the motor efficiency 90%.

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, breannaasmith1122
Two flowing streams of argon gas are adiabatically mixed to form a single flow/stream. one stream is 1.5 kg/s at 400 kpa and 200 c while the second stream is 2kg/s at 500 kpa and 100 ? . it is stated that the exit state of the mixed single flow of argon gas is 150 c and 300 kpa. assuming there is no work output or input during the mixing process, does this process violate either the first or the second law or both? explain and state all your assumptions.
Answers: 1
image
Engineering, 04.07.2019 03:10, lauriepdx17
What precautions should you take to prevent injuries when dealing with heavy loads?
Answers: 1
image
Engineering, 04.07.2019 18:10, anna22684
Water at 70°f and streams enter the mixing chamber at the same mass flow rate, determine the temperature and the quality of the exiting stream. 0 psia is heated in a chamber by mixing it with saturated water vapor at 20 psia. if both streams enters the mixing chamber at the same mass flow rate, determine the temperature and the quality of the existing system.
Answers: 2
image
Engineering, 04.07.2019 18:10, lowkeyqueenk
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
You know the right answer?
A refrigeration plant operates in Pretoria on refrigerant R134a at an evaporator pressure of 105kPa...

Questions in other subjects: