subject
Engineering, 18.08.2020 20:01 zoeatlowapple

Two ideal gases (Inlet 1: H2 and Inlet 2: O2) are mixed in an insulated mixing valve. Assuming no pressure drop in the valve and constant specific heats (evaluated at 300K) determine the following given the conditions below. --Given Values--
Mass flow rate 1: m_H2 (kg/s) = 0.31
Mass flow rate 2: m_O2 (kg/s) = 0.32
T1 (K) = 311
T2 (K) = 404
P (kPa) = 256

a) Determine the molar flow rate (kmol/s) of H2.
Your Answer =
b) Determine the molar flow rate (kmol/s) of O2.
Your Answer =
c) Determine the mixture molecular weight(kg/kmol).
Your Answer =
d) Determine the constant pressure specific heat (kJ/kg-K) of H2 at 300K.
Your Answer =
e) Determine the constant pressure specific heat (kJ/kg-K) of O2 at 300K.
Your Answer =
f) Determine T3.
Your Answer =
g) Determine the rate of entropy production (kW/K) in the valve.
Your Answer =

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, theamandawhite
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
image
Engineering, 04.07.2019 18:10, tjeffers90028
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
image
Engineering, 04.07.2019 18:10, siri5645
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
image
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
You know the right answer?
Two ideal gases (Inlet 1: H2 and Inlet 2: O2) are mixed in an insulated mixing valve. Assuming no pr...

Questions in other subjects:

Konu
Social Studies, 30.07.2019 09:30
Konu
Mathematics, 30.07.2019 09:30