subject
Engineering, 14.08.2020 04:01 kaylaamberd

a ten story building is to be constructed at a site where the water table is close to the ground surface .the foundation of the building will be supported on 30cm diametre pipe piles. the bottom of the pile cap will be at a depth of 1.0m below ground level. the soil investigation at the site and laboratory tests have provided the saturated unit weight, the shear strength values under undrained conditions, the corrected spt values, and the soil profile of the soil to a depth of 40m.

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, hadellolo8839
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 06.07.2019 04:10, blaqsafire9291
Aspherical thermocouple measurement errors a spherical thermocouple made of constantin transfer coefficient between the gas and the thermocouple is h used to measure the temperature of a gas. the heat 400 w/m2 k. calculate the maximum diameter d of the thermocouple if the thermocouple's measurement error should be w 23 within 5% of the initial temperature difference in 5 seconds. for constantin, k 8920 kg/m3, and c 410 j/kg. k.
Answers: 3
image
Engineering, 06.07.2019 04:10, nickmoose04
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 500c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, b)-the mass flow rate of the refrigerant . (c) the heating load and the cop of the pump, and d)-the theoretical minimum power input to the compressor for the same heating load.
Answers: 3
You know the right answer?
a ten story building is to be constructed at a site where the water table is close to the ground sur...

Questions in other subjects: