A facility with 100 L fermentation broth production capacity, will produce bioethanol from Saccharomyces cerevisiae. 1.Accordingly, calculate the stirred tank reactor volume, reactor dimensions (reactor diameter, length, number of impeller, impeller diameter, distance between, etc.).

2.Identify the downstream processes to be installed at this facility and calculate the annual production capacity for 80% yield at each stage.

3.What percentage of our country's production can meet this production capacity?

4.It is planned to use disk centrifuge for cell removal. Calculate the centrifuge speed and time.

5.If sedimentation was used instead of centrifuge, what would be the time necessary to fall down all cells to the bottom of the tank? Compare in terms of efficiency and cost.

6.Glucose will be used as substrate for biotransformation. Taking into account the microorganism production capacity and maintenance, determine the yield, productivity, annual operating cost and investment cost calculations related to production.

7.Also, determine the Monod kinetic constants.

8.Bioethanol production is an anaerobic process. However, suppose that at the beginning of the fermentation, 5 L / min of air was fed to increase the number of cells. Calculate the oxygen transfer rate and oxygen consumption rate.

*You can make the appropriate assumptions for each question (by citing references you used) for the microorganism, cell diameter, production mode, duration and other values to be used in production.

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, tjeffers90028
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
image
Engineering, 04.07.2019 18:10, oliviasoreo92
Compute the pressure drop of 30°c air flowing with a mean velocity of 8 m/s in a circular sheet-metal duct 300 mm in diameter and 15 m long. use a friction factor, f 0.02, and pair = 1.1644 kg/m a. 37.26 pa b. 25.27 pa n c. 29.34 pa d. 30.52 pa
Answers: 1
image
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
image
Engineering, 04.07.2019 19:10, nida7864
An engine, weighing 3000 n, is supported on a pedestal mount. it has been observed that the engine induces vibration into the surrounding area through its pedestal at the maximum operating speed. determine the stiffness of the dynamic vibration absorber spring in (n/m) that will reduce the vibration when mounted on the pedestal. the magnitude of the exciting force is 250 n, and the amplitude of motion of the auxiliary mass is to be limited to 2 mm note: in this question type-in right numbers, no decimals, no fractions, no unit. approximate to right number if needed