A pH sensor is being used to measure real-time changes in pH of a microbial fuel-cell. An A/D converter with 14 bit resolution and a clock of 3.6 MHz is being used to sample and digitize the voltage readings that lie in a range of 0-10V.1. What is the resolution of the voltage signal? 2. What is the maximum error in Volts? 3. How many bits are needed to achieve a maximum error that is less than 0.2 mV? 4. What is the percent maximum error for V in the range (5 - 10](v)? 5. Find the maximum conversion time if the A/D was a successive approximation register (SAR).6. Suppose that the measurement is corrupted by 3-bit white noise, uniformly distributed. What is the variance of the noise in V and what would be the variance if we perform averaging of N values, where N = 2, 5, 107.

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 04.07.2019 18:10, QueenLife4869
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
image
Engineering, 04.07.2019 18:20, 3076850
Prove the equivalence between the two statements of the 2nd law of thermodynamics (i. e., a violation of one statement leads to the violatio the other statement)
Answers: 2
image
Engineering, 04.07.2019 19:10, pjgolden04
How to increase the thermal officiency of an ideal simple rankino cycle? among these methods, which one is the best and why?
Answers: 2