Explain the change in the flow pattern pressure distribution and the lift and drag coefficient for an aerofoil as its angle of attack is increased up to the stall. It is assumed that for a given angle of incidence α (angle of attack), the lift and drag forces that act on an aerofoil are proportional to the dynamic pressure and the plan area S.

Formula for lift (L) and Drag (D) is

L = CL ½?v^2S and D = CD½ ?v^2S where CL = lift coefficient,

CD = Drag coefficient

S = Plan Area (m)

v = air speed (m/s)

The graph below present 'variation of lift and drag coefficient versus angle of incidence α' (angle of attack) where plan area is 60m2 and air speed is 500 km/h.

•TASK 2.7:

From the graph above deduce the data for CL and CD (approx.) when angle of attack is 6ᵒ, and 14ᵒ

Your task is to:

• find the lift and drag forces for each case given above

• with aid of sketches / diagrams, explain:

a. how pressure distribution occurs on aerofoil (in each case)

b. how the air speed can be affected by changing the flow pattern pressure distribution, the lift coefficient and drag coefficient.

c. explain from your result under which condition(s) can an aircraft can be stalled


Explain the change in the flow pattern pressure distribution and the lift and drag coefficient for

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 12:10, Ryantimes2
On a average work day more than work place firs are reorted
Answers: 1
image
Engineering, 04.07.2019 18:10, skpdancer1605
Ariver flows from north to south at 8 km/h. a boat is to cross this river from west to east at a speed of 20 km/h (speed of the boat with respect to the earth/ground). at what angle (in degrees) must the boat be pointed upstream such that it will proceed directly across the river (hint: find the speed of the boat with respect to water/river)? a 288 b. 21.8 c. 326 d. 30.2
Answers: 3
image
Engineering, 04.07.2019 18:20, maustin5323
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
image
Engineering, 04.07.2019 19:20, diawia
Air at a pressure of 1atm and a temperature of 40 c is in parallel flow over the top surface of a flat plate that is heated to a uniform temperature of 120 c. the plate has a length of 0.40m (in the flow direction) and a width of 0.15m. the reynolds number based on the plate length is 50, 000. what is the rate of heat transfer from the plate to the air? if the free stream velocity of the air is doubled and the pressure is increased to 10 atm what is the rate of heat transfer?
Answers: 2
You know the right answer?
Explain the change in the flow pattern pressure distribution and the lift and drag coefficient for a...

Questions in other subjects: