subject
Engineering, 26.04.2020 13:46 SmokeyRN

Using the psychrometric chart, calculate the following:
1. The absolute humidity of air that has RH=40% and a dry bulb temperature 60oC.
2. The wet bulb temperature under these conditions.
3. The RH of air having a wet bulb temperature 44oC and a dry bulb
Temperature 70oC.
4. The dew point of air cooled adiabatically from RH 30% and a dry bulb
Temperature 50oC.
5. The change in RH of air with a wet bulb temperature 38oC, heated from 50oC to
86oC (dry bulb temperatures).

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 19:20, rosemary909
In the winter, in order to keep the classroom steadily at 68 f before 10 pm, heating with an average rate of 42,000 btu/hr is provided. assume the outdoor temperature maintains at 32°f, determine the electrical power (kw) required to (a) operate a reversible heat pump (b) operate a real heat pump with a cop (7) of 4.5 and (c) operate an electrical-resistance heater.
Answers: 3
image
Engineering, 04.07.2019 19:20, lovenahofer
Apreheater involves the use of condensing steam at 100°c on the inside of a bank of tubes to heat air that enters at 1 atm and 25°c. the air moves at 5 m/s in cross flow over the tubes. each tube is 1 m long and has an outside diameter of 10 mm. what is the minimum value of nl needed to achieve an outlet temperature of t 75 c? what is the corresponding pressure drop across the tube bank?
Answers: 3
image
Engineering, 06.07.2019 02:30, onlymyworld27
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
image
Engineering, 06.07.2019 03:10, DeathFightervx
Air is flows through an adiabatic nozzle with an inlet pressure of 400 psia at a temperature of 300°f and a velocity of 20 ft/s. the outlet pressure is 40 psia and the velocity is 800 ftl/s. determine the outlet temperature of the air using: a) property tables b) specific heat (using the specific heat value for air at 300°f)
Answers: 3
You know the right answer?
Using the psychrometric chart, calculate the following:
1. The absolute humidity of air that h...

Questions in other subjects: