![subject](/tpl/images/cats/User.png)
Engineering, 21.04.2020 17:43 Ashleymsmith
The diffusion of a molecule in a tissue is studied by measuring the uptake of labeled protein into the tissue of thickness L =8 um. Initially, there is no labeled protein in the tissue. At t=0, the tissue is placed in a solution with a molecular concentration of C1=9.4 uM, so the surface concentration at x=0 is maintained at C1. Assume the tissue can be treated as a semi-infinite medium. Surface area of the tissue is A = 4.2 cm2. Calculate the flux into the tissue at x=0 and t=5 s. Please give your answer with a unit of umol/cm2 s. Assuming the diffusion coefficient is known of D=1*10-9 cm2/s
![ansver](/tpl/images/cats/User.png)
Answers: 2
![](/tpl/images/ask_question.png)
![](/tpl/images/ask_question_mob.png)
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 03.07.2019 14:10, BardiFan
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 03.07.2019 15:10, brooklyn674
Apiston-cylinder with a volume of 0.25 m3 holds 1 kg of air (r 0.287 k/kgk) at a temperature of 100 c. heat transfer to the cylinder causes an isothermal expansion of the piston until the volume triples. how much heat is added to the piston-cylinder?
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, yasminothman02
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, sarahgrindstaff123
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
You know the right answer?
The diffusion of a molecule in a tissue is studied by measuring the uptake of labeled protein into t...
Questions in other subjects:
![Konu](/tpl/images/cats/fizika.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/en.png)
English, 25.03.2020 20:01
![Konu](/tpl/images/cats/ekonomika.png)
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 25.03.2020 20:02
![Konu](/tpl/images/cats/istoriya.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 25.03.2020 20:02