subject
Engineering, 18.04.2020 00:20 kaileyy06

G The baud rate (e. g. 9600 bps) is the rate at which 1s and 0s are transmitted over the serial line. Briefly explain why the data rate (rate at which useful data is transmitted/received) is less than the baud rate even with error-free transmission. Assume there is always data to send and that no wasteage of bandwidth is due to the lack of data to transmit.

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, skpdancer1605
Ariver flows from north to south at 8 km/h. a boat is to cross this river from west to east at a speed of 20 km/h (speed of the boat with respect to the earth/ground). at what angle (in degrees) must the boat be pointed upstream such that it will proceed directly across the river (hint: find the speed of the boat with respect to water/river)? a 288 b. 21.8 c. 326 d. 30.2
Answers: 3
image
Engineering, 04.07.2019 18:10, bckyanne3
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
image
Engineering, 04.07.2019 19:20, kaitlyn114433
Ashielded metal arc-welding operation is accomplished in a work cell by a fitter and a welder. the fitter takes 5.5 min to load components into the welding fixture at the beginning of the work cycle, and 1.5 min to unload the completed weldment at the end of the cycle. the total ength of the weld seams 1200 mm, and the travel speed used by the welder averages 300 mm/min. every 600 mm of seam length, the welding stick must be changed, which takes 0.8 min. while the fitter is working, the welder is idle (resting): and while the welder is working the fitter is idle. (a) determine the average arc-on time as a fraction of the work cycle time. (b) how much improvement in arc-on time would result if the welder used flux-cored arc welding (manually operated), given that the spool of weld wire must be changed every 10 weldments, and it takes the welder 5.0 min to accomplish the change? (c) what are the production rates for these two cases (weldments completed per hour)? attach your work and solutions.
Answers: 1
image
Engineering, 06.07.2019 03:20, cherkaouinazihp387bk
Figure out the odd statement about ceramics in the following (a) good insulators of heat and electricity (b) usually less desire than metals (c) ductile in nature (d) contains both metallic and nonmetallic elements
Answers: 3
You know the right answer?
G The baud rate (e. g. 9600 bps) is the rate at which 1s and 0s are transmitted over the serial line...

Questions in other subjects:

Konu
Mathematics, 02.12.2021 19:00
Konu
English, 02.12.2021 19:00
Konu
Computers and Technology, 02.12.2021 19:00