subject
Engineering, 15.04.2020 17:27 naansah5457

One hundred electrical components, each dissipating 25 W, are attached to one surface of a square (0.2 m x 0.2 m) copper plate, and all the dissipated energy is transferred to water in parallel flow over the opposite surface. A protuberance at the leading edge of the plate acts to trip the boundary layer, and the plate itself may be assumed to be isothermal. The water velocity and temperature are u_{\infty } = 2 m/s and T_{\infty } = 17o C, and the water's thermophysical properties may be approximated as \nu = 0.96 x 10-6 m2/s, k = 0.620 W/m\cdotk, and Pr = 5.2.

(a) What is the temperature of the copper plate?

(b) If each component has a plate contact surface area of 1 cm2 and the corresponding contact resistance is 2 x 10-4 m2*K/W, what is the component temperature? Neglect the temperature variation across the thickness of the copper plate

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 23:20, abbz13
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
image
Engineering, 04.07.2019 18:10, 19deleonl
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
image
Engineering, 04.07.2019 18:10, jojoangelique13
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
image
Engineering, 04.07.2019 19:20, littlepotato10
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
You know the right answer?
One hundred electrical components, each dissipating 25 W, are attached to one surface of a square (0...

Questions in other subjects:

Konu
Chemistry, 09.11.2020 19:00
Konu
Mathematics, 09.11.2020 19:00