subject
Engineering, 10.04.2020 21:12 Osmin

The decrease_count() function in the previous exercise currently returns 0 if sufficient resources are available and −1 otherwise. This leads to awkward programming for a process that wishes to obtain a number of resources: while (decrease_count(count) == -1) ; Rewrite the resource-manager code segment using a monitor and condition variables so that the decrease_count() function suspends the process until sufficient resources are available. This will allow a process to invoke decrease_count() by simply calling:

decrease_count(count);

The process will return from this function call only when sufficient resources are available.

Previous Code:

#define MAX_RESOURCES 5

int available_resources = MAX_RESOURCES;

When a process wishes to obtain a number of resources, it invokes the decrease_count() function:

/* decrease available_resources by count resources */

/* return 0 if sufficient resources available, */

/* otherwise return -1 */

int decrease_count(int count)

{ if (available_resources < count)

return -1;

else {

available_resources -= count;

return 0;

} }

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 14:10, BardiFan
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
image
Engineering, 03.07.2019 14:10, volleyballfun24
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
image
Engineering, 03.07.2019 15:10, theamandawhite
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
image
Engineering, 04.07.2019 18:10, jadeochoa4466
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false