subject
Engineering, 08.04.2020 02:08 aiguillen6228

Problem 8 (30 points): Below is a general algorithm for plotting the magnitude response of a filter:  Generate a 1 Hz input signal for a large number of samples.  Pass it through the filter and obtain the output.  Compute the ratio of the "rms value of the output sequence" and the "rms value of the input sequence". This ratio is the magnitude response of the filter at 1 Hz.  Repeat this process for 2 Hz, 3 Hz, etc.  Plot the magnitude response (in Y-axis) vs. frequency (in X-axis using a log scale). An N-sample moving average FIR filter is given by, y n = 1 x n − i −1 i=0 , an IIR filter with smoothing parameter, , is given by, y n = 1 − x n + y n − 1 , and a difference filter is given by, y n = x n − x n − 1

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, margaret1758
If you were designing a bumper for a car, would you prefer it to exhibit elastic or plastic deformation? why? consider the functions of a bumper in both a minor "fender-bender" and a major collision.
Answers: 1
image
Engineering, 04.07.2019 08:10, doggo242
Which of the following is an easy way to remember the modified “x” tire rotation? a. nondrive wheels straight, cross the drive wheels b. drive wheels straight, cross the nondrive wheels c. drive wheels crossed, nondrive wheels straight d. drive wheels crossed, nondrive wheels crossed
Answers: 1
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 04.07.2019 18:10, siri5645
At 12 noon, the count in a bacteria culture was 400; at 4: 00 pm the count was 1200 let p(t) denote the bacteria cou population growth law. find: (a) an expression for the bacteria count at any time t (b) the bacteria count at 10 am. (c) the time required for the bacteria count to reach 1800.
Answers: 1
You know the right answer?
Problem 8 (30 points): Below is a general algorithm for plotting the magnitude response of a filter:...

Questions in other subjects:

Konu
Mathematics, 20.05.2021 07:50