Engineering, 23.03.2020 20:00 hamidaakter936848
Consider commuter trains serving contiguous stations. At each station, trains stop to load and unload passengers and this requires a fixed "dwell" time, d. Between stations, trains travel at cruise speed, v. We ignore the effects of acceleration and deceleration. For safety reasons, consecutive trains must always be physically separated by a minimum block distance, b, where block distance is measured from the rear end of a leading train to the front end of the following train. Trains have physical length L. Determine the maximum flow of trains possible given the above operating conditions. Express this maximum flow in terms of the variables given.
Answers: 2
Engineering, 03.07.2019 14:10, makaylashrout77
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
Engineering, 04.07.2019 16:10, TheOriginalMeyah
An electrical motor raises a 50kg load at a construct velencity .calculate the power of the motor, if it takes 40sec to raise the load through a height of 24m(take g =9.8n/g)
Answers: 2
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
Engineering, 04.07.2019 18:20, maustin5323
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
Consider commuter trains serving contiguous stations. At each station, trains stop to load and unloa...
Mathematics, 16.12.2021 21:30
Mathematics, 16.12.2021 21:30
Biology, 16.12.2021 21:30