subject
Engineering, 13.03.2020 03:05 P4thing

A temperature transducer is used to measure the temperature of steam coming out of a steam generator. The following data are available from the manufacturer of the temperature transducer: Range: 0 − 1000 K Sensitivity: ±0.5% of full scale Linearity: ±1.5% of full scale Accuracy: ±1.0% of full scale To determine the repeatability of the transducer, 10 auxiliary tests at the desired average temperature of 800 K were run. The standard deviation of these measurements is 25 K. In a separate test of the data transmission system, 10 tests of the same temperature input resulted in a standard deviation of 20 K. The A/D converter is tested 10 times resulting a standard deviation of 15 K. (a) (10) Calculate the random uncertainty of the temperature measurement at 95% confidence level. (b) (8) Calculate the systematic uncertainty of the temperature measurement. (c) (7) Calculate the total uncertainty of the temperature measurement. If the steam temperature needs to controlled within ±10% from the desired 800 K. Please comment on the adequacy of this device.

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:20, ashleyjaslin
Derive the correction factor formula for conical nozzle i=-(1+ cosa) and calculate the nozzle angle correction factor for a nozzle whose divergence hal-fangle is 13 (hint: assume that all the mass flow originates at the apex of the cone.
Answers: 3
image
Engineering, 04.07.2019 19:20, littlepotato10
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
image
Engineering, 04.07.2019 19:20, amandaaarmentaa
Acircular pipe of 30mm outside diameter is placed in an airstream at 30 c and latm pressure. the air moves in cross flow over the pipe at 20 m/s, while the outer surface of the pipe is maintained at 110 c. what is the drag force exerted on the pipe per unit length? what is the rate of heat transfer from the pipe per unit length?
Answers: 1
image
Engineering, 04.07.2019 19:20, natalie2sheffield
Acompressor compresses a gas, a pump compresses a liquid. for a given pressure ratio, why does it take more work to compress a gas in a compressor than a liquid in a pump? a)- for a given pressure ratio the average specific volume for a gas is much higher than the average specific volume for a liquid. b)- there is no difference. the only difference is the amount of heat generated (not work) c)- for a given pressure ratio the average volurge for a gas is much higher than the average volume for a liquid. d)-there is no difference
Answers: 3
You know the right answer?
A temperature transducer is used to measure the temperature of steam coming out of a steam generator...