subject
Engineering, 07.03.2020 04:19 BigGirlsTheBest

For each of the following problems: design a greedy algorithm that solves the problem; describe your algorithm with clear pseudocode; and prove the time efficiency class of your algorithm.

2-coloring input: an undirected graph G (V, E) output: a sequence coloring-((u, c)IE V and ce(1,2) such that each V appears exactly once in colors , and no adjacent vertices are assigned the same color

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, koolgurl2003
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
image
Engineering, 04.07.2019 19:10, nayi2002
The short distance from the objective lens to the object causes problems at high magnification. which of the following is the most serious? a. cleaning the object surface b. positioning the object c. reflection from the object surface. d. illumination of the object
Answers: 1
image
Engineering, 04.07.2019 19:20, lordcaos066
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
image
Engineering, 06.07.2019 03:20, leapfroggiez
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
You know the right answer?
For each of the following problems: design a greedy algorithm that solves the problem; describe your...

Questions in other subjects:

Konu
Computers and Technology, 16.07.2019 15:10