A Y-connected bank of three identical 100-kVA 9000/300-V2 transformers is supplied with power directly from a large constant-voltage bus. In the short-circuit test, the recorded values on the high-voltage side for one of these transformers are V_SC = 520 I_SC = 10 A P_SC-1 phi = 1100 W (a) If this transformer bank delivers a rated load at 0.88 PF lagging at rated voltage, what is the approximate line-to-line voltage on the primary of the transformer bank? (b) What is the voltage regulation under these conditions? (c) Assume that the primary line voltage of this transformer bank is a constant 520 V, and use Matlab to plot the secondary line voltage as a function of load current for currents from no-load to full-load at power factors of 0.85 lagging, 1.0, and 0.85 leading. Include print out of the Matlab plot and code with your homework. (d) Use Matlab to plot the voltage regulation of this transformer as a function of load current for currents from no-load to full-load at power factors of 0.85 lagging, 1.0, and 0.85 leading. Include a copy of Matlab plot and code with your homework.

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 23:20, abbz13
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
image
Engineering, 04.07.2019 18:10, hadellolo8839
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
image
Engineering, 04.07.2019 18:10, abdirahmansoloman
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
image
Engineering, 04.07.2019 18:10, lillygrl100
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
You know the right answer?
A Y-connected bank of three identical 100-kVA 9000/300-V2 transformers is supplied with power direct...