In this problem you will estimate the heat lost by a typical house, assuming that the temperature inside is Tin=20∘C and the temperature outside is Tout=0∘C. The walls and uppermost ceiling of a typical house are supported by 2×6-inch wooden beams (kwood=0.12W/(mK)) with fiberglass insulation (kins=0.04W/(mK)) in between. The true depth of the beams is actually 5.625 inches, but we will take the thickness of the walls and ceiling to be Lwall=18cm to allow for the interior and exterior covering. Assume that the house is a cube of length L=9.0m on a side. Assume that the roof has very high conductivity, so that the air in the attic is at the same temperature as the outside air. Ignore heat loss through the ground.

The effective thermal conductivity of the wall (or ceiling) keff, is the area-weighted average of the thermal conductivities of the wooden beams and the fiberglass insulation that make up each of them. Allowing for the fact that the 2×6 beams are actually only 1.625 inches wide and are spaced 16 inches center to center, a calculation of this conductivity for the walls yields keff=0.048W/(mK). For simplicity, assume that the ceiling also has the same value of keff.

Part A What is H, the total rate of energy loss due to heat conduction for this house? Round your answer to the nearest 10 W.

Part B Let us assume that the winter consists of 150 days in which the outside temperature is 0∘C. This will give the typical number of "heating degree days" observed in a winter along the northeastern US seaboard. (The cumulative number of heating degree days is given daily by the National Weather Service and is used by oil companies to determine when they should fill the tanks of their customers.) Given that a gallon (3.4 kg) of oil liberates Qg=1.4×108J when burned, how much oil will be needed to supply the heat lost by conduction from this house over a winter? Assume that the heating system is 75% efficient.

Give your answer numerically in gallons to two significant figures.

Expert Answer

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 03.07.2019 15:10, theamandawhite
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
image
Engineering, 04.07.2019 19:10, babas97
What is a monomer? how do they form a ploymer from the view point of chemical bonding?
Answers: 1
image
Engineering, 04.07.2019 19:20, molly7654
Brief discuss how the presence of dislocations in crystal structures can be an advantage and a disadvantage to engineer and designers.
Answers: 3
You know the right answer?
In this problem you will estimate the heat lost by a typical house, assuming that the temperature in...