subject
Engineering, 24.02.2020 16:55 SavyBreyer

Your cement company manufactures a cement with the following composition: 55% C3S, 18% C2S, 10% C3A, 8% C4AF, and 6% CŜH2 with a Blaine fineness of 365 m2 /kg. a. A customer has complained that the 1-day strengths are low. List 2 things you can change in your production to address this and what the consequences of those two things are on the composition and properties listed above. b. Which of the two changes in (a) are you more likely to implement, and why? c. All of a sudden there is a high demand for gypsum and the price has skyrocketed. What can you do to your cement to reduce the amount of gypsum needed? What would a potential consequence of this change be?

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, hadellolo8839
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
image
Engineering, 04.07.2019 18:10, Candi9697
A-mn has a cubic structure with a0 0.8931 nm and a density of 7.47 g/cm3. b-mn has a different cubic structure, with a0 0.6326 nm and a density of 7.26 g/cm3. the atomic weight of manganese is 54.938 g/mol and the atomic radius is 0.112 nm. determine the percent volume change that would occur if a-mn transforms to b-mn.
Answers: 2
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
image
Engineering, 04.07.2019 18:20, miguel454545
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
Your cement company manufactures a cement with the following composition: 55% C3S, 18% C2S, 10% C3A,...

Questions in other subjects:

Konu
Mathematics, 12.02.2021 02:30
Konu
Mathematics, 12.02.2021 02:30
Konu
Mathematics, 12.02.2021 02:30
Konu
Mathematics, 12.02.2021 02:30
Konu
Mathematics, 12.02.2021 02:30