subject
Engineering, 14.02.2020 04:24 NathanaelLopez

Consider a column of length 5 meters standing vertically up on the floor. Treat the column as a 1-D structure and ignore its weight. The super- structure placed on the top of the column applies a weight of 1kN along the center line (a vertical line passing through the centroids of the cross sections) of this column. Assume that the column has a built-in (fixed) support to the ground. The material testing performed in the laboratory shows that the column could shrink by 2% for a 100N compressive internal for ce. (a) Draw the free-body diagram of the column. Identify, body, boundary, displacement prescribed boundary, and force prescribed boundary. Calculate the reaction forces at the support considering the global equilibrium of the column. (b) Determine the internal force of a material section at a height of 2.5 meters from the bottom of the column. If you choose a material point at a different location is the intern al force going to be different? (c) Determine the deformation of a material section located at 2.5 meters from the bottom (d) Estimate the displacement at four locations of the column; 1) at the base, 2) 1/3rd the height of the column from the base, 3) 2/3rd the height of the column from the base, and 4) the top of the column. (Displacement is the actual motion of the location) (e) Calculate the deflection of 1) the bottom half of the column, 2) the top half of the column and 3) the whole column.

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, Talos02
Burgers vector is generally parallel to the dislocation line. a)-true b)-false
Answers: 2
image
Engineering, 04.07.2019 18:10, aliopqwas
Condition monitoring is a major component of. (clo4) a)- predictive maintenance. b)-preventive maintenance c)-proactive maintenance d)-reactive maintenance.
Answers: 1
image
Engineering, 04.07.2019 18:10, wirchakethan23
Hydraulic fluid with a sg. of 0.78 is flowing through a 1.5 in. i. d. pipe at 58 gal/min. the fluid has an absolute viscosity of 11.8 x 105 lbf-sec/ft2. is the flow laminar, turbulent or within the critical range? give both a numerical reynolds number and a term answer.
Answers: 3
image
Engineering, 04.07.2019 18:10, oshawn108
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg. k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m. k
Answers: 2
You know the right answer?
Consider a column of length 5 meters standing vertically up on the floor. Treat the column as a 1-D...

Questions in other subjects:

Konu
Mathematics, 30.11.2020 20:30
Konu
Mathematics, 30.11.2020 20:30