The molar volume (cm3 mol-1) of a binary liquid mixture at T and P is given by:
V = 120X...
![subject](/tpl/images/cats/User.png)
Engineering, 13.02.2020 18:51 merrylsimpson
The molar volume (cm3 mol-1) of a binary liquid mixture at T and P is given by:
V = 120X1+70X2 +(15X1+8X2)X1X2
a. Find expressions for the partial molar volumes of species 1 and 2 at T and P.
b. Show that when these expressions are combined in accord with the given equation for V is recovered. M= Sigma XiMi
c. Show that these expressions satisfy the Gibbs-Duhem equation Sigma XidMi=0
d. Show that (dV1/dX1)x1=1=(dV2/dX1)x1=0
e. Plot, using a graphing software, the values of V, V1, and V2 calculated by the given equation for V and by the equations developed in (a) vs X1. Label points V1, V2, Vinfinity1, and V infinity2, and show their value.
![ansver](/tpl/images/cats/User.png)
Answers: 1
![](/tpl/images/ask_question.png)
![](/tpl/images/ask_question_mob.png)
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, Strick1530
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, salazjlove
Which of the following refers to refers to how well the control system responds to sudden changes in the system. a)-transient regulation b)- distributed regulation c)-constant regulation d)-steady-state regulation
Answers: 1
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
Questions in other subjects:
![Konu](/tpl/images/cats/mat.png)
Mathematics, 03.10.2019 02:30
![Konu](/tpl/images/cats/istoriya.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/himiya.png)
![Konu](/tpl/images/cats/geografiya.png)
Geography, 03.10.2019 02:30
![Konu](/tpl/images/cats/en.png)
![Konu](/tpl/images/cats/biologiya.png)
Biology, 03.10.2019 02:30
![Konu](/tpl/images/cats/mat.png)
Mathematics, 03.10.2019 02:30