subject
Engineering, 12.02.2020 03:18 madelyngv97

A rigid tank contains liquid water and water vapor with an initial total internal energy of 500 kJ. During the process over 1 minute, 900 kJ of energy are transferred into the system from a burner and 50 A of electrical current was supplied to the resistor at the voltage of 110 V. As a result, 800 kJ are transferred from water to the surrounding air.(a) What kind of work interaction is present in this process? Consider the walls of the rigid tank as the system.
(b) Is this process adiabatic?
(c) After this process the volume of the tank will change?
(d) Calculate the final internal energy of the water contained in the tank (neglect the energy stored in the tank walls).

ansver
Answers: 1

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, settasav9641
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
image
Engineering, 04.07.2019 19:10, thawkins79
Agas contained within a piston-cylinder assembly e end nation about same energy states, 1 and 2, where pi 10 bar, v undergoes two processes, a and b, between the sam 0.1 m3, ui-400 kj and p2 1 bar, v2 1.0 m2, u2 200 kj: process a: process from 1 to 2 during which the pressure- volume relation is pv constant process b: constant-volume process from state 1 to a pressure of 2 bar, followed by a linear pressure-volume process to +20 0 state 2 kinetic and potential energy effects can be ignored. for each of the processes a and b, (a) sketch the process on p-v coordinates, (b) evaluate the work, in kj, and (c) evaluate process the heat transfer, in kj
Answers: 2
image
Engineering, 04.07.2019 19:20, praveen35301
Amass-spring-viscous damper system of mass 3 kg has a frequency of 100 rad/s and is critically damped. its initial conditions are x(0)-3 mm and (0)-2.3 m/s. does the system overshoot its equilibrium position? prove your answer
Answers: 1
image
Engineering, 06.07.2019 04:10, makenziemartinez
Aheat pump using refrigerant-134a heats a house by using underground water at 8°c as the heat source. the house is losing heat at a rate of 60,000 kj/h. the refrigerant enters the compressor at 280 kpa and 0°c, and it leaves at 1 mpa and 60°c. the refrigerant exits the condenser at 30°c. determine: (a) the power input to the heat pump, (b) the rate of heat absorption from the water, and (c) the increase in electric power input if an electric resistance heater is used instead of a heat pump
Answers: 2
You know the right answer?
A rigid tank contains liquid water and water vapor with an initial total internal energy of 500 kJ....

Questions in other subjects: