The output voltage is given by the voltage divider equation: v_2 = v_1 r_2/r_1 + r_2. suppose the voltage source produces a voltage of v_1 = 5v with an accuracy of plusminus 10mv, the resistor r_1 has a nominal value of 1k ohm with a tolerance of plusminus 5%, and we measure the voltage v_2 with our voltmeter to be 3.5v and we know the error in our voltmeter reading to be plusminus 20mv. if we use the above voltage divider equation to calculate the value of the resistor, r_2, include the following derivations in your prelab: (1) what is the calculated value of r_2? (2) what kind of error should we expect in our calculated value of r_2? that is, what is the maximum and minimum amount we could expect to be off by?

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, lowkeyqueenk
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
image
Engineering, 04.07.2019 18:20, luisgonz5050
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
image
Engineering, 04.07.2019 18:20, 21megoplin
How much power could a wind turbine produce if it had the following specifications? cp = 0.45 -d=1.2kg/m3 d=50m v 5m/s
Answers: 2
image
Engineering, 04.07.2019 19:10, gabrielaperezcz
Air inially occupying a volume of 1 m2 at 100 kpa, 27 c undergoes three internally reversible processes in series. process 1-2 compression to 500 kpa during which pv constant process 2-3 adiabatic expanslon to 100 kpa process 3-1: constant-pressure expansion to 100 kpa (a) calculate the change of entropy for each of the three processes. (b) calculate the heat and work involved in each process. (c) is this cycle a power cycle or refrigeration cycle?
Answers: 3
You know the right answer?
The output voltage is given by the voltage divider equation: v_2 = v_1 r_2/r_1 + r_2. suppose the v...