Engineering, 28.12.2019 04:31 prettygirl321490

Geothermal water, t_hi-95 c, is to be used in a double pipe counter-flow heat exchanger to heat cold water, tci-12 c, c,-41 80 j/kg-k flowing at l .2 kg/s to tc,-50 c for household use. the cold water will flow through the inner tube of the copper thin-walled heat exchanger, di 0.03761 m (1%"type k tubing). for safety reasons the size of the heat exchanger is to be limited in order to limit the outlet temperature of the cold water. assuming chot> ccold (note: c-m cp) and that the heat transfer coefficients on the hot and cold sides are approximately equal (hc -hh) what is the maximum allowable length of the heat exchanger? density of both streams is p 1000 kg/m', kter 0.615 w/m-k, h-0.798 x 10 kg/m-s, pr 5.4 (12.0 m)

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, lowkeyqueenk
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:10, Larkinlover703
Items are similar to the free issue items, but their access is limited. (clo5) a)-bin stock items free issue b)-bin stock controlled issue c)-critical or insurance spares d)-rebuildable spares e)-consumables
Answers: 1
image
Engineering, 04.07.2019 18:20, CelesteN64
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
You know the right answer?
Geothermal water, t_hi-95 c, is to be used in a double pipe counter-flow heat exchanger to heat cold...

Questions in other subjects:

Konu
English, 01.09.2021 19:50
Konu
Mathematics, 01.09.2021 19:50