subject
Engineering, 27.12.2019 07:31 tsbrunson13

The composition of the feed to a debutaniser is given below. make a preliminary design for a column to recover 98 per cent of the n-butane overhead and 95 per cent of the isopentane from the column base. the column will operate at 14 bar and the feed will be at its boiling point. use the short-cut methods and follow the procedure set out below. use the de priester charts to determine the relative volatility. the liquid viscosity can be estimated using the data given in appendix d.
(a) investigate the effect of reflux ratio on the number of theoretical stages. (b) select the optimum reflux ratio. (c) determine the number of stages at this reflux ratio. (d) estimate the stage efficiency. (e) determine the number of real stages. (f) estimate the feed point. (g) estimate the column diameter.

feed composition (kg/h):
propane c3 (910 kg/h)
isobutane i-c4 (180 kg/h)
n-butane n-c4 (270 kg/h)
isopentane i-c5 (70 kg/h)
normal pentane n-c5 (90 kg/h)
normal hexane n-c6 (20 kg/h)

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, mm016281
What difference(s) did you notice using a pneumatic circuit over hydraulic circuit. explain why the pneumatic piston stumbles when it hits an obstacle.
Answers: 2
image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:10, mamasbug4285
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
image
Engineering, 04.07.2019 18:20, sarah7984
Vibration monitoring this technique uses the noise or vibration created by mechanical equipment and in seme cases by plant systems to detemine their actual condtion. a)- true b)- false
Answers: 2
You know the right answer?
The composition of the feed to a debutaniser is given below. make a preliminary design for a column...

Questions in other subjects:

Konu
Mathematics, 12.10.2020 14:01
Konu
Arts, 12.10.2020 14:01
Konu
Mathematics, 12.10.2020 14:01
Konu
Mathematics, 12.10.2020 14:01