![subject](/tpl/images/cats/User.png)
Engineering, 20.12.2019 21:31 neariah24
Is it possible to produce a continuous and oriented aramid fiber-epoxy matrix composite having longitudinal and transverse moduli of elasticity of 35 gpa (5 × 10^6 psi) and 4.48 gpa (6.50 × 10^5 psi), respectively? assume that the elastic moduli of the epoxy and aramid fiber are 3.4 gpa (4.93 × 10^5 psi) and 131 gpa (9.0 × 10^6 psi), respectively. write yes or no.
![ansver](/tpl/images/cats/User.png)
Answers: 2
![](/tpl/images/ask_question.png)
![](/tpl/images/ask_question_mob.png)
Other questions on the subject: Engineering
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:10, michellerosas
Ajournal bearing has a journal diameter of 3.250 in with a unilateral tolerance of 20.003 in. the bushing bore has a diameter of 3.256 in and a unilateral tolerance of 0.004 in. the bushing is 2.8 in long and supports a 700-lbf load. the journal speed is 900 rev/min. find the minimum oil film thickness and the maximum film pressure for both sae 20 and sae 20w-30 lubricants, for the tightest assembly if the operating film temperature is 160°f. a computer code is appropriate for solving this problem.
Answers: 3
![image](/tpl/images/cats/User.png)
![image](/tpl/images/cats/User.png)
![image](/tpl/images/cats/User.png)
Engineering, 04.07.2019 18:20, maciemarklin79981
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
You know the right answer?
Is it possible to produce a continuous and oriented aramid fiber-epoxy matrix composite having longi...
Questions in other subjects:
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/mat.png)
![Konu](/tpl/images/cats/geografiya.png)
Geography, 19.02.2021 02:50
![Konu](/tpl/images/cats/mat.png)
Mathematics, 19.02.2021 02:50
![Konu](/tpl/images/cats/istoriya.png)
![Konu](/tpl/images/cats/himiya.png)
Chemistry, 19.02.2021 02:50
![Konu](/tpl/images/cats/mat.png)
Mathematics, 19.02.2021 02:50
![Konu](/tpl/images/cats/istoriya.png)
![Konu](/tpl/images/cats/mat.png)
Mathematics, 19.02.2021 02:50