subject
Engineering, 30.11.2019 02:31 ingridx0

Argon and methane are absorbed from nitrogen into liquid ammonia at 252.3 k and 175.0 atm. feed rate of gas is 100 kmol/h. feed gas contains 0.020 mol% ar and 0.130 mol% methane. outlet gas contains 0.0008 mol% methane. the entering liquid ammonia is pure. the system operates with l/v = 26.0. assume l and v flow rates are constant. equilibrium data for methane is, partial pressure methane = 3600 atm and the partial pressure for argon = 7700 atm. a. find the outlet mole fraction of methane in the liquid b. find the number of equilibrium stages required. c. find the outlet mole fraction of argon in the gas.

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, aaliyah80
The drive force for diffusion is 7 fick's first law can be used to solve the non-steady state diffusion. a)-true b)-false
Answers: 1
image
Engineering, 04.07.2019 18:10, 0436500
Aturning operation is performed with following conditions: rake angle of 12°, a feed of 0.35 mm/rev, and a depth of cut of 1.1 mm. the work piece is aluminum alloy 6061 with t6 heat treatment (a16061-t6). the resultant chip thickness was measured to be 1.0 mm. estimate the cutting force, fc. use shear stress of 207 mpa and coefficient of friction on the tool face of 0.6.
Answers: 1
image
Engineering, 04.07.2019 18:20, maustin5323
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
image
Engineering, 06.07.2019 03:10, kturvey225
Consider a 1.2 meter high and 2 meter wide glass window whose thickness is 6 mm and thermal conductivity is 0.78 w/m °c. the room temperature is maintained at 24 °c, while the outdoor temperature is -5 °c. the convective heat transfer coefficients on the inner and outer surfaces of the window are 10 w/m2 °c and 25 w/m2 °c respectively. (a) draw the thermal resistance network, etermine the steady rate of heat transfer t e glass window (c) determine the temperature of the inner surface of the window
Answers: 3
You know the right answer?
Argon and methane are absorbed from nitrogen into liquid ammonia at 252.3 k and 175.0 atm. feed rate...

Questions in other subjects:

Konu
English, 25.11.2020 01:00
Konu
Engineering, 25.11.2020 01:00
Konu
Arts, 25.11.2020 01:00