22.5-4. minimum liquid flow in a packed tower. the gas stream from a chemical reactor contains 25 mol % ammonia and the rest are inert gases. the total flow is 181.4 kg mol/h to an absorption tower at 303 k and 1.013 × 105 pa pressure, where water containing 0.005 mol frac ammonia is the scrubbing liquid. the outlet gas concentration is to be 2.0 mol % ammonia. what is the minimum flow l min ⁡ ′ using 1.5 times the minimum, plot the equilibrium and operating lines. ans. l min ⁡ ′ = 262.6kg mol/h

ansver
Answers: 3

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, jadeochoa4466
The temperature of air decreases as it is compressed by an adiabatic compressor. a)- true b)- false
Answers: 2
image
Engineering, 04.07.2019 18:10, caitlynnpatton1208
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
image
Engineering, 04.07.2019 18:20, moneywaydaedae
Air is compressed isentropically from an initial state of 300 k and 101 kpa to a final temperature of 1000 k. determine the final pressure using the following approaches: (a) approximate analysis (using properties at the average temperature) (b) exact analysis
Answers: 1
image
Engineering, 04.07.2019 18:20, maciemarklin79981
A3-mm-thick panel of aluminum alloy (k 177 w/m-k, c 875 j/kg-k and ? = 2770 kg/m) is finished on both sides with an epoxy coating that must be cured at or above t,-150°c for at least 5 min. the production line for the curing operation involves two steps: (1) heating in a large oven with air at ts,0-175°c and a convection coefficient of h, 40 w/m2. k, and (2) cooling in a large chamber with air at 25°c and a con- vection coefficient of he 10 w/m2.k. the heating portion of the process is conducted over a time interval te which exceeds the ime required to reach 150°c by 5 min (h = r + 300 s). the coating has an emissivity of ? = 0.8, and the temperatures of the oven and chamber walls are 175 and 25°c, respectively. if the panel is placed in the oven at an initial temperature of 25°c and removed from the chamber at a safe-to-touch tempera ture of 37°c, what is the total elapsed time for the two-step curing operation?
Answers: 3
You know the right answer?
22.5-4. minimum liquid flow in a packed tower. the gas stream from a chemical reactor contains 25 mo...

Questions in other subjects:

Konu
Mathematics, 02.12.2021 01:00
Konu
Spanish, 02.12.2021 01:00
Konu
Mathematics, 02.12.2021 01:00