subject
Engineering, 27.11.2019 21:31 didilove456

The barometer in the lab indicates a pressure of 1013 minibar and the thermometer indicates a temperature of 22 degree c. in our flow lab, we used a pitot-static tube to measure transverse velocity of air flowing through a circular pipe, and the pitot-static tube is connected to a pressure transducer. the following data is collected, where the first column is the radial location from the centerline (in cm) and the second column is the average voltage measured at this location (in volts). the pipe inside diameter is measured to be 10.4cm. what is the air density in the lab? a calibration curve y=0.006x, where y is in volts and in pascal, was previously obtained for the pressure transducer. what is the air velocity, in m/s, at each radial location? what is the volume flow rate of the air, in m^3/s? what is the mass flow rate of the air, in kg/s? what is the average velocity of the air flow, in m/s?

ansver
Answers: 2

Other questions on the subject: Engineering

image
Engineering, 04.07.2019 18:10, Strick1530
Which of the following components of a pid controlled accumulates the error over time and responds to system error after the error has been accumulated? a)- proportional b)- derivative c)- integral d)- on/off.
Answers: 2
image
Engineering, 04.07.2019 18:20, sarah7984
Vibration monitoring this technique uses the noise or vibration created by mechanical equipment and in seme cases by plant systems to detemine their actual condtion. a)- true b)- false
Answers: 2
image
Engineering, 04.07.2019 18:20, kendrawalraven
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
image
Engineering, 04.07.2019 18:20, xcapo1x
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
You know the right answer?
The barometer in the lab indicates a pressure of 1013 minibar and the thermometer indicates a temper...

Questions in other subjects: